Home         | Company         | Technical             | Sales |

Solar Home Heating & Night Air Cooling 

View Movies

Solectair/Evaporative Aircon

Solectair/Gas/
Refrigerated Aircon

Stand-Alone Solectair



TV Shows

ABC New Inventors

Eco House Challenge



Downloads

Solectair Brochure
(306Kb)

Hot Air - Sunday
Times article
(144Kb)

Solectair Owners
Guide
(199Kb)

Installation Guide
(263Kb)

Greenhouse Gas Emissions

Table 5 lists the greenhouse gas emissions for an electric resistive heater system, a ducted gas system, a reverse-cycle air-conditioner, a Solectair only system, a Solectair with gas assist and a Solectair with reverse-cycle air-conditioner assist. The values for all cases (with the exception of the Solectair Only case) is for the systems to supply 5013 kWh of heat as per Table 1. In the Solectair Only case, the heat supplied is 3526 kWh. The data is also shown in Graph 18 (over).


Table 5:
Greenhouse Gas Emissions for different heating systems.

MONTH   Resistive electric
(kgCO2)
Ducted Gas
(kgCO2)
RC Electric
(kgCO2)
Solectair Only
(kgCO2)
Solectair + Gas
(kgCO2)
Solectair + RC Electric
(kgCO2)
Jan 0 0 0 0 0 0
Feb 0 0 0 0 0 0
Mar 0 0 0 0 0 0
Apr 28 8 10 9 9 9
May 492 139 176 49 49 49
Jun 1260 348 443 39 158 191
Jul 1458 399 509 18 277 349
Aug 1029 280 358 50 80 88
Sep 519 140 180 65 65 65
Oct 192 52 66 82 82 82
Nov 35 9 12 15 15 15
Dec 0 0 0 0 0 0
Total 5010 kgCO2 1375 kgCO2 1755 kgCO2 326 kgCO2 734 kgCO2 847 kgCO2

The Solectair HTS gives a very considerable greenhouse gas (GHG) emissions reduction. For a house similar to that as the Solectair Test House, the addition of a Solectair HTS to a ducted gas heating system can reduce the GHG emissions by as much as 53%. A Solectair HTS fitted to a reverse cycle air-conditioner can reduce the GHG emissions by as much as 48%.

 

Graph 18: Greenhouse Gas Emissions from different heating systems to supply 5013 kWh (3855 kWh for Solectair only System).

 


Table 11: Kilograms of CO2 reductions per year.

Location Solectair + natural gas vs. natural gas only
(kgCO2/year)
Solectair + reverse-cycle electric vs. reverse-cycle electric (kgCO2/year) Solectair + reverse-cycle electric vs. resistive electric (kgCO2/year)
Adelaide 740 1030 7140
Albany* 740 970 7610
Canberra 580 780 13750
Brisbane 940 1240 4660
Melbourne 1370 1780 10610
Perth 640 910 4170
Sydney 940 1240 4660

*GHG emissions from gas for Albany is based upon LPG, not natural gas.

 


Home | Company | Technical | University Test Results | Retail & Trade Sales
Licence Opportunities | Greenhouse Gas Emissions